Sale!

Syringe Pump Driver KL605T

R13,418.90 R12,681.90

Syringe Pump KL605T

Specifications
Model KL-605T
Syringe Sizes 5,10, 20, 30, 50/60 ml
Applicable Syringe Compatible with syringe of any standard
VTBI 1-1000 ml in 0.1 , 1 , 10 ml increments

Flow Rate

Syringe 5ml : 0.1-100 ml/h (in 0.01 , 0.1 , 1 , 10ml/h increments)

Syringe 10 ml: 0.1-300 ml/h
Syringe 20 ml: 0.1-600 ml/h
Syringe 30 ml: 0.1-800 ml/h

Syringe 50/60 ml: 0.1-1200 ml/h
Bolus Rate Syringe :

5ml: 0.1-100ml/h (in 0.01 , 0.1 , 1 , 10ml/h increments)

10 ml: 300 ml/h Syringe

20 ml: 600 ml/h Syringe

30 ml: 800 ml/h Syringe

50/60 ml: 1200 ml/h
Anti-Bolus Automatic
Accuracy ±2% (mechanical accuracy ≤1%)
Infusion Mode

Flow rate: ml/min, ml/h
Time-based
Body weight
KVO Rate 0.1-1 ml/h (in 0.01 ml/h increments)
Alarms Occlusion, near empty, end program, low battery, end battery,
AC power off, motor malfunction, system malfunction, reminder alarm,
pressure sensor error, syringe installation error, syringe drop off
Additional Features Real-time infused volume, automatic power switching,
automatic syringe identification, mute button, purge, bolus, anti-bolus,
system memory
Drug Library Available

History log :50 000 events
Occlusion Sensitivity High, medium, low
Power Supply, AC 110/230 V (optional), 50/60 Hz, 20 VA
Battery 14.8 V, rechargeable
Battery Life 8 hours at 5 ml/h
Working Temperature 5-40℃
Relative Humidity 20-90%
Atmospheric Pressure 700-1060 hpa
Size 245*120*115 mm
Weight 2.5 kg
Safety Classification Class II, type BF

Description

 

Syringe Pump KL605T

Specifications
Model KL-605T
Syringe Sizes 5,10, 20, 30, 50/60 ml
Applicable Syringe Compatible with syringe of any standard
VTBI 1-1000 ml in 0.1 , 1 , 10 ml increments

Flow Rate

Syringe 5ml : 0.1-100 ml/h (in 0.01 , 0.1 , 1 , 10ml/h increments)

Syringe 10 ml: 0.1-300 ml/h
Syringe 20 ml: 0.1-600 ml/h
Syringe 30 ml: 0.1-800 ml/h

Syringe 50/60 ml: 0.1-1200 ml/h
Bolus Rate Syringe :

5ml: 0.1-100ml/h (in 0.01 , 0.1 , 1 , 10ml/h increments)

10 ml: 300 ml/h Syringe

20 ml: 600 ml/h Syringe

30 ml: 800 ml/h Syringe

50/60 ml: 1200 ml/h
Anti-Bolus Automatic
Accuracy ±2% (mechanical accuracy ≤1%)
Infusion Mode

Flow rate: ml/min, ml/h
Time-based
Body weight
KVO Rate 0.1-1 ml/h (in 0.01 ml/h increments)
Alarms Occlusion, near empty, end program, low battery, end battery,
AC power off, motor malfunction, system malfunction, reminder alarm,
pressure sensor error, syringe installation error, syringe drop off
Additional Features Real-time infused volume, automatic power switching,
automatic syringe identification, mute button, purge, bolus, anti-bolus,
system memory
Drug Library Available

History log :50 000 events
Occlusion Sensitivity High, medium, low
Power Supply, AC 110/230 V (optional), 50/60 Hz, 20 VA
Battery 14.8 V, rechargeable
Battery Life 8 hours at 5 ml/h
Working Temperature 5-40℃
Relative Humidity 20-90%
Atmospheric Pressure 700-1060 hpa
Size 245*120*115 mm
Weight 2.5 kg
Safety Classification Class II, type BF