Showing all 7 results

Aseptor Bags Out Of Stock

Aseptor Bags

Aseptor Bags

Used to enclose items to be sterilized.

Manufactured from medical grade paper complying with SANS 50868 Parts 1 & 3

Has a distinctive process indicator which changes colour when exposed to steam sterilization

Complies with CKS 595

Various sizes :

No.1   89mm x 51mm x 102mm Pack 1000

No.2   89mm x 229mm  Pack 1000

No.3 114mm x 36mm x 190mm Pack 1000

No.4  127mm x 48mm x 260mm Pack 1000

No.5 127mm x 85mm x 229mm Pack 1000

No.6 192mm x 62mm x 318mm Pack 1000

No.7  178mm x 74mm x 380mm Pack 1000

No.8 64mm x 34mm x 483mm Pack 1000

No.9 120mm x 135mm Pack 1000

No.11 292mm x 127mm x 444mm Pack 500

No.12 330mm x 152mm x 559mm Pack 500

No.13 257mm x 108mm x 381mm Pack 1000

No.25 64mm x 36mm x 152mm Pack 1000

No.1020 64mm x 36mm x 203mm Pack 1000

No.3050 64mm x 36mm x 254mm Pack 1000

Sale!
Bowie Dick Test Pack 50

Bowie Dick Test Pack 50

R2,198.90 R1,978.90

Bowie Dick Test Pack 50

BOWIE-DICK TESTS:
A Bowie-Dick test is used in pre-vacuum type (or dynamic air removal) sterilizers. They are used to detect air leaks and inadequate air removal and consist of folded 100% cotton surgical towels that are clean and preconditioned. A commercially available Bowie-Dick-type test sheet should be placed in the center of the pack.
The test pack should be placed horizontally in the front, bottom section of the sterilizer rack, near the door and over the drain, in an otherwise empty chamber and run at 134°C for 3.5 mi nutes. The test is used each day the vacuum-type steam sterilizer is used, before the first processed load.
Air that is not removed from the chamber will interfere with steam contact. Smaller, commercially available disposable test packs (or process challenge devices) have been devised to replace the stack of folded surgical towels for testing the efficacy of the vacuum system in a pre vacuum sterilizer.
They should be representative of the load and simulate the greatest challenge to the load. Sterilizer vacuum performance is acceptable if the sheet inside the test pack shows a uniform color change. Entrapped air will cause a spot to appear on the test sheet, due to the inability of the steam to reach the chemical indicator. If the sterilizer fails the Bowie-Dick test, do not use the sterilizer until it is inspected by the sterilizer maintenance personnel and passes the Bowie-Dick test.

Sale!
Bowie Dick Test Sheets per 50

Bowie Dick Test Sheets per 50

R328.90 R295.90

Bowie Dick Test Sheets

BOWIE-DICK TESTS:
A Bowie-Dick test is used in pre-vacuum type (or dynamic air removal) sterilizers. They are used to detect air leaks and inadequate air removal and consist of folded 100% cotton surgical towels that are clean and preconditioned. A commercially available Bowie-Dick-type test sheet should be placed in the center of the pack.
The test pack should be placed horizontally in the front, bottom section of the sterilizer rack, near the door and over the drain, in an otherwise empty chamber and run at 134°C for 3.5 mi nutes. The test is used each day the vacuum-type steam sterilizer is used, before the first processed load.
Air that is not removed from the chamber will interfere with steam contact. Smaller, commercially available disposable test packs (or process challenge devices) have been devised to replace the stack of folded surgical towels for testing the efficacy of the vacuum system in a pre vacuum sterilizer.
They should be representative of the load and simulate the greatest challenge to the load. Sterilizer vacuum performance is acceptable if the sheet inside the test pack shows a uniform color change. Entrapped air will cause a spot to appear on the test sheet, due to the inability of the steam to reach the chemical indicator. If the sterilizer fails the Bowie-Dick test, do not use the sterilizer until it is inspected by the sterilizer maintenance personnel and passes the Bowie-Dick test.

Ultra Violet Sterilizer 30 WATT Cami

Ultra Violet Sterilizer 30 WATT Cami

R5,263.09

Steriliser Ultra Violet 30 WATT Cami

FEATURES :

  • Violet is a germicidal system which uses an ultraviolet germicidal lamp
  • This Violet maintains sterility of instruments and small disposables after sterilization in an autoclave or similar type of sterilization unit
  • Stainless steel body
  • Inexpensive, reliable, safe, easy operation and maintenance
Ultra Violet Sterilizer 8 Watt or 15 Watt Out Of Stock

Ultra Violet Sterilizer 8 Watt or 15 Watt

Sterilizer Ultra Violet 8 Watt or 15 Watt

FEATURES :
• Violet is a germicidal system which uses an ultraviolet germicidal lamp
• This Violet maintains sterility of instruments and small disposables after sterilization in an autoclave or similar type of sterilization unit
• Stainless steel body
• Inexpensive, reliable, safe, easy operation and maintenance